logo
Brans Measuring And Controlling Technology Co., Ltd
produits
produits
Maison > produits > Cellule de charge à point unique > Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Détails de produit

Lieu d'origine: Chine

Nom de marque: BRANS

Numéro de modèle: Le numéro WL-116

Documents: WL-116 Single Point Load Ce...NS.pdf

Conditions de paiement et d'expédition

Quantité de commande min: 1 pièces

Détails d'emballage: Emballage standard en carton d'exportateur, y compris les instructions.

Délai de livraison: 5-7 jours ouvrables

Conditions de paiement: LC, T/T, Western Union, Paypal

Obtenez le meilleur prix
Mettre en évidence:
Taper:
Cellule de charge de sortie analogique
Capacité de charge:
5 kg/10 kg/20 kg/30 kg/50 kg/100 kg/200 kg, pour une période de trois mois à compter de la date de d
Taille du câble:
Φ5,4 × 4000 mm
Erreur combinée:
± 0,01% F.S.
Taille maximale de la plateforme:
600 mm × 500 mm
Surcharge sûre:
150%F.S.
Surcharge finale:
300% F.S.
Personnalisable:
Personnalisable
Température de fonctionnement.:
-30 ~ 70 ° C
Taper:
Cellule de charge de sortie analogique
Capacité de charge:
5 kg/10 kg/20 kg/30 kg/50 kg/100 kg/200 kg, pour une période de trois mois à compter de la date de d
Taille du câble:
Φ5,4 × 4000 mm
Erreur combinée:
± 0,01% F.S.
Taille maximale de la plateforme:
600 mm × 500 mm
Surcharge sûre:
150%F.S.
Surcharge finale:
300% F.S.
Personnalisable:
Personnalisable
Température de fonctionnement.:
-30 ~ 70 ° C
Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready


Product Description:

Struggling to find a single point load cell that balances capacity with precision? The WL-116 single point load cell offers a solution, covering everything from 5kg light-duty scales to 200kg industrial platforms—all with C3/C4 accuracy.

Off-center loading errors are a common headache in weighing systems. The WL-116 single point load cell addresses this with a optimized structure that minimizes sensitivity to uneven weight distribution, ensuring that this single point load cell delivers accurate readings regardless of load position.

Need to build a larger platform? No problem. The WL-116 single point load cell is engineered for output uniformity, meaning multiple units of this single point load cell can be connected in parallel without complex calibration routines. Each single point load cell in the series shares the same electrical and mechanical characteristics.

For automated production lines, the WL-116 single point load cell offers the speed and stability required for dynamic weighing. Whether integrated into a checkweigher or a filling system, this single point load cell responds quickly and maintains accuracy over millions of cycles.

From agriculture to chemical processing, the WL-116 single point load cell has proven its worth in harsh environments. If you need a single point load cell that delivers precision, consistency, and long-term reliability, the WL-116 is the answer.

Specifications:



Capacity 5kg/10kg/ 20kg/ 30kg/ 50kg/ 100kg/200kg
Rated output

2.0±10%mV/V

Accuracy class C3/C4
Combined error ±0.01%F.S. 
Zero balance ±0.2%mV/V
Non-linearity ±0.017%F.S.
Hysteresis ±0.017%F.S.
Repeatability ±0.01%F.S.
Creep (30min) ±0.017%F.S.
Temperature effect on sensitivity ±0.017%F.S./10℃
Temperature effect on zero ±0.02%F.S./10℃
Input resistance 420±20Ω
Output resistance 350±10Ω
Insulation resistance ≥5000MΩ/100VDC
Recommended excitation 5-15VDC
Compensated temp. range -10~40℃
Operation temp. range -10~50℃
Safe overload 150%F.S.
Ultimate overload 300%F.S.
IP class IP68 (Customizable)
Cable size Φ5.2×4000mm (Customizable)
Material Aluminum alloy
Max.platform size 600mm×500mm






Dimension(MM):

     

           Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 0                    


                                       


Load Direction:

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 1
 

Wiring:

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 2

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 3

Why the WL-116 Single Point Load Cell Solves Your Weighing Challenges Wide Capacity Range: 5kg–200kg | C3/C4 Accuracy | Parallel Ready 4

Load Cell Packaging and Shipping


To ensure safe arrival at your location, the load cell will be carefully packaged and shipped. The packing process is as follows:

1. The load cell will be placed in a sturdy cardboard box to protect it from external damage during shipping.
2. The box will be filled with foam padding to provide additional cushioning and prevent the load cell from moving during shipping.
3. The load cell will be sealed in a plastic bag to protect it from moisture and other environmental factors.
4.  Additional layers of bubble wrap will be provided for additional protection.
5. The carton is securely taped to prevent tampering.
6. A shipping label with your address and product information is attached to the box.
7. The package is shipped using a reliable and trusted freight carrier.


Once the package is shipped, you will receive a tracking number to monitor the status of your delivery. Please ensure that someone is available at the delivery address to receive the package to avoid any delays or problems.